Tools

Practical calculators and utilities for engineering teams

25 tools found

AVAILABLE

Instrumentation

4–20 mA Scaling Calculator

Convert engineering units to/from 4–20 mA signal values. Useful for PLC/DCS scaling configuration.

⭐ FEATURED
AVAILABLE

Instrumentation

I/O Card Selector

Enter I/O point counts by signal type (DI, DO, AI, AO, RTD, TC) and get the quantity and model of I/O cards to specify. Covers PLC platforms (Allen-Bradley, Siemens, Schneider M580 & TriconCX) and DCS platforms (Emerson DeltaV, Honeywell Experion, Yokogawa CENTUM, ABB AC 800M) with spare capacity.

AVAILABLE

Instrumentation

Junction Box Capacity Estimator

Estimate terminal block count, DIN rail utilization, and cable gland schedule for junction box sizing.

AVAILABLE

Instrumentation

RTD / Thermocouple Quick Reference

Temperature vs resistance/millivolt lookup for PT100, PT1000, Ni100 and thermocouple types J, K, T, E, N, R, S, B. Includes sensor comparison table.

AVAILABLE

Instrumentation

Instrument Cable Voltage Drop

Calculate voltage drop for instrument signal cables over distance.

AVAILABLE

Electrical

Voltage Drop Calculator

Calculate voltage drop for power cables based on load, cable size, and distance.

AVAILABLE

Electrical

Motor FLA Estimator

Estimate full load amps for AC motors based on HP/kW and voltage.

⭐ FEATURED
ADVANCED

Electrical

Generator Load Estimator

Estimate generator sizing from a connected load list with demand factors and motor starting inrush (DOL, Star-Delta, Soft Starter, VFD). Standby/Prime/Continuous duty, altitude derating, planning margin, voltage-dip check, CSV & printable report.

AVAILABLE

Process

Restriction Orifice Sizing

Preliminary restriction orifice (RO) sizing for gas and single-phase liquid services using differential-pressure & compressible-flow equations. Critical/subcritical detection via critical pressure ratio, multi-stage equal-ratio distribution, cavitation/flashing screening. Steam and two-phase flashing are not certified methods here. SI & US Customary.

AVAILABLE

Process

Orifice Plate Sizing Calculator

Preliminary orifice plate sizing for natural gas using a Reader-Harris/Gallagher discharge-coefficient form (ISO 5167-2 equation structure) with flange taps. Solve for flow rate or bore diameter. Includes an optional gas chromatography module for Z-factor (Hall-Yarborough) and SG from composition. Not a certified ISO 5167 / AGA-3 / API MPMS 14.3 custody-transfer calculation.

AVAILABLE

Instrumentation

Control Valve Cv Calculator

Calculate required valve flow coefficient (Cv) for liquid and gas services using ISA/IEC 60534-2-1 equations.

⭐ FEATURED
ADVANCED

Instrumentation

Control Valve Sizing Calculator

Preliminary control-valve sizing for liquid, gas and steam per IEC 60534-2-1 / ISA-75.01.01. Required Cv/Kv, recommended nominal size, choked/cavitation/flashing checks, multi-case (min/normal/max), lead & printable report. Preliminary — not for final procurement or safety-critical design.

⭐ FEATURED
AVAILABLE

Process

Pipe Sizing Tool

Verifies line hydraulics (liquid/gas/multiphase): velocity, frictional ΔP/L and API 14E erosion via Darcy–Weisbach/Colebrook and Beggs & Brill. Editable acceptance criteria and batch line sizing, with auto-size and exports. Preliminary — not a certified calculation.

AVAILABLE

Process

Pressure Unit Converter

Convert between PSI, bar, kPa, MPa, kg/cm², and inH₂O.

AVAILABLE

Process

Temperature Converter

Convert between Celsius, Fahrenheit, Kelvin, and Rankine.

AVAILABLE

Process

Gas Flow Unit Converter

Convert gas flow rates between SCFM, SCFH, MMSCFD, Nm³/h, and other units.

⭐ FEATURED
AVAILABLE

Process

Flare Radiation Calculation

Preliminary flare thermal-radiation calculation per API 521 (simple point-source method): heat release, flame length, wind-relative flame geometry, atmospheric transmissivity, optional solar baseline, exclusion radii, receiver flux, and required stack height. Not a substitute for Brzustowski-Sommer, solid-flame, or CFD siting.

⭐ FEATURED
AVAILABLE

Process

Separator Preliminary Sizing

Preliminary screening of horizontal/vertical two-phase and three-phase oil & gas separators (Souders–Brown gas capacity + liquid retention holdup). ID, L/H, L/D, gas velocity vs allowable, retention checks, bilingual, unit systems, traceable calculation details. Screening only — not certified API 12J / GPSA or mechanical design.

AVAILABLE

Commissioning

HART Loop Resistance Checker

Verify HART loop resistance compliance and transmitter voltage on a 4–20 mA HART analogue loop before commissioning. Checks total loop resistance ≥ HART modem minimum (typ. 250 Ω) and supply voltage at the device.

AVAILABLE

Electrical

kW / HP / Amp Conversion

Convert between kilowatts, horsepower, and amperes for motors and loads. Bidirectional power↔current with motor context (voltage, phases, power factor, efficiency).

⭐ FEATURED
ADVANCED

Process

Pressure Safety Valve (PSV) Sizing

Preliminary PSV sizing per API RP 520 Part I for gas/vapor, liquid and steam services. Multi-case relief scenarios, API 526 orifice selection (D-T), choked-flow detection and oversize-margin check. Lead-gated PDF datasheet for procurement. Preliminary — not for final procurement or safety-critical design.

AVAILABLE

Electrical

Power Factor Calculator

Calculate apparent, real, and reactive power from power factor and kVA.

AVAILABLE

Commissioning

Commissioning Punch List

Printable punch list template for pre-commissioning and commissioning activities.

ADVANCED

Commissioning

FAT Checklist Generator

Factory Acceptance Test checklist based on system type.

ADVANCED

Commissioning

SAT Checklist

Site Acceptance Test checklist for instrumentation and control systems.